• ENMA.jpg

Front of Wall Component - Active Sense

Touch free sensor tap with a beneath outlet infra-red sensor activation is designed for general hand hygiene within health care and food preparation facilities. Designed for effective reduction of Legionella risk. Features flush cycles and smooth bore spout design. Adjustable temperature range for user comfort. AHFG Type A and B healthcare basin compatibility. Smart, durable easy-clean chrome surfaces and sealed face plate minimises egress of moisture into wall cavity and contaminated air flow from wall cavity into sterile areas.

Key features

  • Smooth bore tubular spout designed to minimise bacteria growth
  • 12-hour flush cycle eliminates stagnation in water supply lines greatly reducing the risk of bacteria growth
  • Potentially contaminated air is elminated from the water stream with laminar flow controlled spout
  • Low voltage 6V battery operated or 12V mains supply
  • Back and front of wall components are separate order codes and can be supplied separately to meet construction needs
  • Face plate removes to access integral isolation/check valves, strainers and inspection ports for TMV servicing requirements
  • Products

    Order code Front of Wall Component - Active Sense
    ENMABC1L3
    200mm Spout 8Lpm Laminar Flow
    ENMABC1L5
    200mm Spout 6Lpm Laminar Flow
    ENMABC1L6
    200mm Spout 4.73Lpm Laminar Flow
    ENMABC2L3
    230mm Spout 8Lpm Laminar Flow
    ENMABC2L5
    230mm Spout 6Lpm Laminar Flow
    ENMABC2L6
    230mm Spout 4.73Lpm Laminar Flow
    ENMAMC1L3
    200mm Spout 8Lpm Laminar Flow
    ENMAMC1L5
    200mm Spout 6Lpm Laminar Flow
    ENMAMC1L6
    200mm Spout 4.73Lpm Laminar Flow
    ENMAMC2L3
    230mm Spout 8Lpm Laminar Flow
    ENMAMC2L5
    230mm Spout 6Lpm Laminar Flow
    ENMAMC2L6
    230mm Spout 4.73Lpm Laminar Flow
    Note: Due to Voltage variation the Battery front must be matched with ENM620 Battery In wall component. Mains powered front must be match with ENM621.
  • Inlet Connection 15mm (1/2") BSP
    Minimum-Maximum Working Pressure (AS/NZS 3500)* 50-500kPa*
    Maximum Static Pressure 800kPa
    Maximum Temperature 70 C*
    Time Flow Specifications ENM5071 Adjustable flow time to 3, 6, 9 or 12 seconds. (Default 6 seconds)
    Wave-On Wave-Off Specifications ENM5072 45 seconds maximum run time if not waved off by user.
    Power Supply 24V AC
    Sensor Range Approx. 170mm
    *Enware products are to be installed in accordance with AS/NZS3500. NOTE: Enware Australia advises:1. Due to ongoing Research and Development, specifications may change without notice. 2. Component specifications may change on some export models.
  • Document type File type
    Installation guide pdf
Email Us