• ATMS729.jpg

Aquablend 2500 - Stainless Steel Box and Lid Only

Anti-tamper, lockable stainless steel box for easier installation and servicing. The durable box has a brushed stainless cover plate and includes a mounting bracket for the TMV. Recessed model with oversized fascia and adjustable depth to allow for various wall types. Suits the Aquablend 2500 model.

Key features

  • Products

    Order code Aquablend 2500 - Stainless Steel Box and Lid Only
    ATMS728
    Stainless Steel Wall Mounting Bracket Recessed
    ATMS729
    Exposed
  • Temperature Adjustment Range 35 to 50C
    Dynamic Inlet Pressures 10kPa Min - 500kPa Max
    Static Inlet Pressure 1000kPa Max
    Flow Rates 75 litres/minute@300kPa pressure loss
    Minimum Flow Rate for stable outlet temperature 6 litres/min
    Inlet size 3/4" BSP FI
    Outlet size 1" BSP MI
    Inlet Temperatures Cold Supply: Min 5 C Max 30 C Hot Supply: Min 55 C Max 90 C
    For optimum operation it is recommended that the hot and cold water supply pressures be balanced within +/- 10%. Hot to Mix temperature differential required for stable operation is minimum 10C. * Enware products are to be installed in accordance with the Plumbing Code of Australia and AS/NZS3500. NOTE: Enware Australia advises: 1. Due to ongoing Research and Development, specifications may change without notice. 2. Component specifications may change on some export models.