• ATM715.jpg

Aquablend 1500 - Solar Model

Aquablend's technology provides superior control, under changing pressure and temperature conditions as well as at ambient start up when scald protection is needed most. The proven performance, reliability and low 'whole of life' cost makes Aquablend a popular choice with specifiers, engineers, plumbers and property owners. Aquablend 1500 Solar is the first Australian TMV specifically designed for solar hot water systems. Featuring greater temperature handling capability with the same performance, reliability and ease of servicing you have come to expect from the Aquablend range.

Key features

  • Australian design and manufacture and Standards Licensed to AS4032.1
  • Scald and thermal shock protection with rapid thermal shut-off should either the cold or hot water supply failure
  • Highly responsive mixed temperature control (+/- 2 Degrees Celcius) under changing inlet temperature and pressure conditions
  • Delivers excellent flow, operating at a minimum pressure of 20kPa
  • Supplied complete with isolating valves, non-returns and dual stage strainers incorporating temperature/pressure test ports
  • Flexible installation - inlet and outlet connections may be rotated to suit pipework design
  • Products

    Order code Aquablend 1500 - Solar Model
    ATM715
    Includes Isolation Valves
  • Temperature Adjustment Range 38 to 50C
    Dynamic Inlet Pressures 20kPa Min - 500kPa Max
    Static Inlet Pressure 1600kPa Max
    Flow Rates 39lpm@300kPa pressure loss
    Minimum Flow Rate for stable outlet temperature 4 litres/min
    Inlet size 1/2" compression nuts
    Outlet size 1" complete with 1"x1/2" & 1"x 3/4" BSP adaptors
    Inlet Temperatures Cold Supply: Min 5 C Max 30 C Hot Supply: Min 55 C Max 99 C
    For optimum operation it is recommended that the hot and cold water supply pressures be balanced within +/- 10%. Hot to Mix temperature differential required for stable operation is minimum 10C. * Enware products are to be installed in accordance with the Plumbing Code of Australia and AS/NZS3500. NOTE: Enware Australia advises: 1. Due to ongoing Research and Development, specifications may change without notice. 2. Component specifications may change on some export models.