• ATMS2009R.jpg

Aquablend 1000 - 4-Hole (South Aust) Lockable Stainless Steel Cabinet

Aquablend's technology provides superior control, under changing pressure and temperature conditions and at ambient start up when scald protection is needed most. Aquablend 1000 has an adjustable temperature range up to 50 Degrees Celcius to also suit residential applications. Lockable stainless steel box for easier installation and servicing. The durable box with brushed stainless cover plate and includes TMV mounted on support bracket, fully plumbed with test port on outlet and cold by-pass with isolation point. Recessed model has oversized fascia and adjustable depth for various wall types.

Key features

  • Australian design and manufacture and Standards Licensed to AS4032.1
  • Scald and thermal shock protection with rapid thermal shut-off should either the cold or hot water supply failure
  • Highly responsive mixed temperature control (+/- 2 Degrees Celcius) under changing inlet temperature and pressure conditions
  • Delivers excellent flow, operating at a minimum pressure of 20kPa
  • Supplied complete with TMV mounted on support bracket, fully plumbed with test port on outlet and cold bypass with isolation
  • Access panel is removable for easy access especially in small spaces or near walls - Hinged door option available
  • Products

    Order code Aquablend 1000 - 4-Hole (South Aust) Lockable Stainless Steel Cabinet
    ATMS2009R
    Recessed Box and Removable Lid
  • Temperature Adjustment Range 38 to 50C
    Dynamic Inlet Pressures 20 kPa Min - 500 kPa Max
    Static Inlet Pressure 1600 kPa Max
    Flow Rate 39 lpm @ 300 kPa Pressure Loss
    Minimum Flow Rate for Stable Outlet Temperature 4 litres / min
    Inlet Size DN20 Copper Tube (Type B 19.05mm OD) Valve Connection: 1/2" BSP
    Outlet Size DN20 Copper Tube (Type B 19.05mm OD) Valve Connection: 1" BSP with 1/2" BSP Adaptor
    Inlet Temperatures Cold Supply: Min 5 C Max 30 C Hot Supply: Min 55 C Max 90 C
    For optimum operation it is recommended that the hot and cold water supply pressures be balanced within +/- 10%. Hot to Mix temperature differential required for stable operation is minimum 10C. * Enware products are to be installed in accordance with the Plumbing Code of Australia and AS/NZS3500. NOTE: Enware Australia advises: 1. Due to ongoing Research and Development, specifications may change without notice. 2. Component specifications may change on some export models.
  • ATM710B3 Line Drawing
  • Document type File type
    Brochure I Aquablend - Product Guide
    Installation guide pdf
    PDF Dimensional Drawings ATMS2009R
Email Us